May 29, 2017 | Sachse, TX

After checking out the pool system, we cleaned the filter and found several bad grades which we replaced. We also recharged the filter with a DE and the system now runs as intended.

May 28, 2017 | Dallas, TX

They were having a major celebration in four days and we were able to install a new pool pump motor quickly so the pool would be in top working order for the party.

May 24, 2017 | Plano, TX

We installed a new backwash valve, 4 Jandy valves, check valves, and cleaned the filter. Her Polaris 280 was worn out and we replaced it with a new one She also needed a dual time clock with freeze guard in one enclosure, which we did.

May 23, 2017 | Richardson, TX

We did this for him and rewired the pool pump inside the timer box.

May 17, 2017 | Richardson, TX

Our owner went to give an estimate for replacement. Everything needed to be replaced. We installed a new pool pump, motor, piping, electrical wiring, a new pool sweep booster pump, related plumbing, Jandy valves, new 48sqft DE filter, backwash valve, related plumbing, new time clocks for the pool/booster pump, ...

May 17, 2017 | Plano, TX

We re-tiled his pool with an upgraded tile and re-plastered with aqua blue mini pebble plaster. We also installed a new 48 square-foot Pentair DE filter, backwash valve, and plumbing. In addition, we installed a 1.5 HP Pentair super flow pool pump, an LED color-changing light fixture, and a handrail.

May 16, 2017 | Plano, TX

Because they were not going to re-plaster the pool, we acid-washed the plaster to remove construction debris, chlorine wash to sanitize, and we balanced the chemicals.

May 15, 2017 | Dallas, TX

We did a filter clean and found three bad grades and the top manifold to the DE filter was bad. We replaced these items and got the filter running and then cleaned and shocked the pool.

May 12, 2017 | Dallas, TX

We installed a new pool timer mechanism and also found a leak on the pool pump. We repaired that by installing a seal and gasket.

May 10, 2017 | Dallas, TX

We examined the skimmer line and realized it had not been addressed in years. But we were able to clear the line and the swimming pool now has proper circulation.

May 9, 2017 | Dallas, TX

The pool needed a special chemical treatment for phosphates and RX balls and we replaced the spa fountain check valve. The filter pressure was also high so we cleaned it. After those tweaks, the pool runs wonderfully.

May 2, 2017 | Richardson, TX

One of our technicians went to his house to diagnose the problem. He found that the booster pump's capacitor needed to be replaced and it switched on by either the timer or manually flipping the switch.

April 24, 2017 | Dallas, TX

Our owner went to his house to diagnose the problem and repair. After taking a few panels off he discovered multiple rodents nests built inside. He had to remove and completely clean the rodent nests from the top and bottom of the heater. This is a very dirty and smelly ...

April 24, 2017 | Dallas, TX

We scheduled a filter clean service for him. When we were doing the work, our technician found the top manifold inside the filter was cracked and broken in multiple places. We got approval to replace the broken parts and reassembled the filter. Everything worked perfectly after this work was done.

April 24, 2017 | Dallas, TX

We took the heater apart and found a rodents nest on the top and bottom inside of the heater. We cleaned the pool heater out and it works OK.